GMP Technical Solutions Pvt. Ltd.

Cleanroom Equipment


Cleanroom equipment is of utmost importance for its intended use in any cleanroom facility. All the equipment comes with a factory tested certificate and required documentation. All GMP products are manufactured under one roof and subsequently all metal finishes, assembly are completed in-house. As a result, specific requirements of client can be incorporated into a proposed design.

 


Business Type Manufacturer, Exporter, Trader
Power Supply 230V AC 1-Ø 50HZ

Preferred Buyer From

Location Worldwide

In any pharmaceutical manufacturing facility it is essential to minimise man / material movement & avoid cross contamination between different classified areas to achieve desired classification & to maintain integrity of products & process.

 

The Passboxes are designed to allow material transfer without much personnel movement. It also ease controlling ingress of particulate contaminants into the cleanroom & between different classified areas.

 

General Specifications : 

  • Double Walled Construction
  • Doors with double walled flush glass view panels
  • SS Handles & SS hinges
  • Internal covings for easy cleaning
  • Electro-magnetic Interlocking
  • Door Release Switch on either side
  • Indicator on either side

 

Options and Accessories :

  • Mechanical Interlocking
  • Provision for ventilation with perforated grille
  • U. V. Light with Hour Meter with interlocking arrangement to put-off U.V. Light if either door opens
  • Three wall construction in case of floor mounting
  • Floor mounted contruction with three side wall structure & Door Drop Seal
  • Support stand to mount the pass box
  • Flange for sealing the gap between the pass box and the cleanroom wall
Read More...


Yes! I am interested


Business Type Manufacturer, Exporter, Trader
Brand Name GMP
Air cleanliness ISO Class 5 (ISO 14644-1:1999 (E))
Air Velocities 0.45 ± 0.05 mps
Air Flow Vertical - Recirculatory
Noise Level Less than 67 dB
Vibration Level Minimum
Power Supply 230v Ac 1-ø 50hz

Preferred Buyer From

Location Worldwide

In any pharmaceutical manufacturing facility it is essential to minimise man / material movement & avoid cross contamination between different classified areas to achieve desired classification & to maintain integrity of products & process.

 

The Passboxes are designed to allow material transfer without much personnel movement. It also ease controlling ingress of particulate contaminants into the cleanroom & between different classified areas.

 

General Specifications

  • Two Stage filtration
  • EU6 – Prefilter (95% down to 5 micron)
  • EU14 - HEPA Filter – Supply (99.999% down to 0.3 micron)
  • Statically & Dynamically balanced Motor-blower with suspension arrangement to reduce noise level
  • Doors with double walled flush glass view panels
  • SS Handles & SS hinges
  • Internal covings for easy cleaning
  • Electro-magnetic Interlocking
  • Indicator on either side
  • Door Release Switch on either side
  • Differential Pressure Gauge : 1 No
  • On / Off Switch for Motor
  • DOP Test Port

 

Options and Accessories

  • Mechanical Interlocking
  • U. V. Light with Hour Meter with interlocking arrangement to put-off U.V. Light if either door opens
  • Floor mounted contruction with three side wall structure & Door Drop Seal
  • Support Stand to mount the pass box
  • Flange for sealing the gap between the pass box and the cleanroom wall
Read More...


Yes! I am interested


Business Type Manufacturer, Exporter, Trader
Brand Name GMP
Air cleanliness ISO Class 5 (ISO 14644-1:1999 (E))
Air Velocities 0.45 ± 0.05 mps
Air Flow Horizontal
Noise Level Less than 67 dB
Vibration Level Minimum
Light intensity > 300 lux
Power Supply 230V AC 1-Ø 50HZ

Click to view more

Preferred Buyer From

Location Worldwide

Laminar Air Flows are designed to offer the highest product protection for samples and processes by providing ISO Class 5 particle free work area. The LAFs with various air-flow patterns offer proven protection for the samples and processes. The work area is continuously supplied with positive pressure HEPA filtered air flow.

 

General Specifications

  • Glass Side panels
  • Two Stage filtration
  • EU6 – Prefilters (95% down to 5 micron)
  • EU14 - HEPA Filter (99.999% down to 0.3 micron) at supply position
  • Statically & Dynamically balanced Motor-blower with suspension arrangement to reduce noise level
  • SS work table with due reinforcement
  • Fluorescent Lights with Milky White Diffuser
  • Differential Pressure Gauge : 1 No
  • ON/OFF Switches
  • Clean Down Timer with Operation HOLD indicator
  • DOP Test Port
  • 5/15 Amp Switch Socket for external equipment

 

Options and Accessories

A wide range of configurations to suit any containment application :

  • Front doors (hinged/pneumatic cylinder)
  • U. V. Light with Hour Meter
  • Air / Gas Cock
  • Night Mode Operation
  • Filter blocked alarms (audible and visible)
  • Velocity display with alarms (audible and visible)
  • Explosion proof electrics for Flame-proof applications
Read More...


Yes! I am interested


Business Type Manufacturer, Exporter, Trader
Brand Name GMP
Air cleanliness ISO Class 5 (ISO 14644-1:1999 (E))
Air Velocities 0.45 ± 0.05 mps
Air Flow Vertical
Noise Level Less than 67 dB
Vibration Level Minimum
Light intensity > 300 lux
Power Supply 230V AC 1-Ø 50HZ

Click to view more

Preferred Buyer From

Location Worldwide

Laminar Air Flows are designed to offer the highest product protection for samples and processes by providing ISO Class 5 particle free work area. The LAFs with various air-flow patterns offer proven protection for the samples and processes. The work area is continuously supplied with positive pressure HEPA filtered air flow.

 

General Specifications

Two Stage filtration

  • EU6 – Prefilter (95% down to 5 micron)
  • EU14 - HEPA Filter (99.999% down to 0.3 micron) at supply position
  • Statically & Dynamically balanced Motor-blower with suspension arrangement to reduce noise level
  • SS work table with due reinforcement
  • Glass side panels
  • Fluorescent Lights with Milky White Diffuser
  • Differential Pressure Gauge : 1 No
  • ON/OFF Switches
  • Clean Down Timer with Operation HOLD indicator
  • DOP Test Port
  • 5/15 Amp Switch Socket for external equipment

 

Options and Accessories

A wide range of configurations to suit any containment application :

  • Front doors (hinged/pneumatic cylinder)
  • U. V. Light with Hour Meter
  • Air / Gas Cock
  • Night Mode Operation
  • Velocity display with alarms (audible and visible)
  • Filter blocked alarms (audible and visible)
  • Explosion proof electrics for Flame-proof applications
Read More...


Yes! I am interested


Business Type Manufacturer, Exporter, Trader
Brand Name GMP
Air cleanliness ISO Class 5 (ISO 14644-1:1999 (E))
Air Velocities 0.45 ± 0.05 mps
Air Flow Vertical - Recirculatory
Noise Level Less than 67 dB
Vibration Level Minimum
Light intensity > 300 lux
Power Supply 230V AC 1-Ø 50HZ / 415V AC 3- Ø 50HZ

Click to view more

Preferred Buyer From

Location Worldwide

Laminar Air Flows are designed to offer the highest product protection for samples and processes by providing ISO Class 5 particle free work area. The LAFs with various air-flow patterns offer proven protection for the samples and processes. The work area is continuously supplied with positive pressure HEPA filtered air flow.

 

General Specifications

  • Triple Stage filtration
  • EU4 - Prefilters (90% down to 10 micron)
  • EU7 - Intermediate Filter (95% down to 3 micron)
  • EU14 - HEPA Filter - Supply / Exhaust (99.999% down to 0.3 micron)
  • Statically & Dynamically balanced Motor-blower with suspension arrangement to reduce noise level
  • Double skin puff filled side panels
  • Horizontal internal Covings at base
  • Fluorescent Lights with Milky White Diffuser
  • Differential Pressure Gauges : 3 Nos
  • ON/OFF Switches
  • Clean Down Timer with Operation HOLD indicator
  • DOP Test Port5/15 Amp Sw
  • itch Socket for external equipment

 

Options and Accessories

A wide range of configurations to suit any containment application :

  • Double skin side panels with view windows
  • Stainless steel perforated grille for HEPA Filter
  • Front Anti Static PVC Curtains (for warehouse applications)
  • Front doors (hinged/sliding/rapid roller)
  • SS Stand alone table for keeping Weighing Scale
  • Sodium Vapor Lamps
  • Night Mode Operation
  • Velocity display with alarms (audible and visible)
  • Filter blocked alarms (audible and visible)
Read More...


Yes! I am interested


Business Type Manufacturer, Exporter, Trader
Air cleanliness ISO Class 5 (ISO 14644-1:1999 (E))
Air Velocities 0.45 ± 0.05 mps
Air Flow Horizontal
Noise Level Less than 67 dB
Vibration Level Minimum
Power Supply 230V AC 1-Ø 50HZ

Preferred Buyer From

Location Worldwide

Mobile Trolley is designed for transporting sterile products under ISO Class 5 (Class 100) particle free work area. The work area is continuously supplied with positive pressure HEPA filtered recirculated horizontal air flow.

 

General Specifications

  • Two Stage filtration
  • EU6 – Prefilter (95% down to 5 micron) for return air & fresh air intake
  • EU14 - HEPA Filter (99.999% down to 0.3 micron) at supply position
  • Statically & Dynamically balanced Motor-blower with suspension arrangement to reduce noise level
  • Differential Pressure Gauge : 1 No.
  • SS 304 removable Shelves
  • SS 304 doors with double walled flush glass view panels
  • SS 304 handle for mobility
  • Battery back-up with inverter for 30 mins
  • PU coated Lockable castor wheels
  • ON/OFF Switches
  • DOP Test Port

 

Options and Accessories

A wide range of configurations to suit any containment application :

  • Velocity display with alarms (audible and visible)
  • Filter blocked alarms (audible and visible)
  • Explosion proof electrics for Flame-proof applications
  • Blower tripping alarms (audible and visible)
Read More...


Yes! I am interested


Business Type Manufacturer, Exporter, Trader
Brand Name GMP
Air Velocities 0.45 ± 0.05 mps
Air Flow Vertical - Recirculatory
Noise Level Less than 67 dB
Vibration Level Minimum
Light intensity > 300 lux
Power Supply 230V AC 1-Ø 50HZ / 415V AC 3-Ø 50HZ

Preferred Buyer From

Location Worldwide

Bio Safety Cabinet is designed to provide personnel, environmental and product protection. Air flow is drawn around the operator into the front grille of the cabinet, which provides personnel protection.

 

In addition, the downward laminar flow of HEPA-filtered air provides product protection by minimizing the chance of cross-contamination along the work surface of the cabinet. Because cabinet air passes through the exhaust HEPA filter, it is contaminant-free (environmental protection).

 

All Class II cabinets are designed for work involving microorganisms assigned to biosafety levels 1, 2 and 3. Class II cabinets provide the microbe-free work environment necessary for

cell culture propagation, and also may be used for the formulation of nonvolatile antineoplastic or hemotherapeutic drugs.

 

General Specifications

  • Two Stage filtration
  • EU6 - Intermediate Filter (95% down to 6 micron)
  • EU14 - HEPA Filter - Supply / Exhaust (99.999% down to 0.3 micron)
  • Statically & Dynamically balanced Motor-blower with suspension arrangement to reduce noise level
  • Double walled flushed Glass Side Panels
  • SS 304 work table with perforations at front & back which can be removed occasionally for cleaning purpose
  • 1-piece fully openable sliding toughened glass front door with counterweight arrangement
  • Sealed Fluorescent Lights with Milky White Diffuser
  • Differential Pressure Gauges : 2 Nos.
  • ON/OFF Switches for motor & Lights
  • Clean Down Timer with Operation HOLD indicator
  • Alarm triggers in case front door is raised more than 8” (i.e. safe clear opening during operation)
  • DOP Test Port
  • 5/15 Amp Switch Socket for external equipment
  • SS 304 stands with leveling lugs
  • SS 304 1 ft long elbow duct for exhaust

 

Options and Accessories

A wide range of configurations to suit any containment application :

  • Night Mode Operation
  • Filter blocked alarms (audible and visible)
  • Velocity display with alarms (audible and visible)
  • Explosion proof electrics for Flame-proof applications
  • Once through System
  • Front doors with Glove arrangement
  • Transfer hatch for material movement
  • PLC based Control System
  • Safe change Bag in/Bag out arrangement for filters
Read More...


Yes! I am interested


Business Type Manufacturer, Exporter, Trader
Brand Name GMP
Air cleanliness ISO Class 5 (ISO 14644-1:1999 (E))
Air Velocities 18 - 20 mps
Vibration Level Minimum
Power Supply 415V AC 3-Ø 50HZ

Preferred Buyer From

Location Worldwide

Air Shower/Mist Shower is designed to supply Class 100 HEPA filtered air at high velocity to remove particulate matter from the person entering into the Clean Room.

 

General Specifications

  • Two Stage filtration
  • EU6 - Prefilter (95% down to 5 micron) for return air & fresh air intake
  • EU14 - HEPA Filter (99.999% down to 0.3 micron) at supply position
  • SS 304 doors with double walled flush glass view panels & door closer
  • Statically & Dynamically balanced Motor-blowers with suspension arrangement to reduce noise level for suction and booster
  • Differential Pressure Gauge : 1 No
  • ON/OFF Switches
  • DOP Test Port
  • 5/15 Amp Switch Socket for external equipment
  • Control Systems – to ensure that both the doors cannot open at the same time & to ensure that both the door will be locked during the time air flow is on
  • Timer for setting Air Shower operation time (settable for 30 seconds to 5 minutes)
  • Emergency STOP
  • Straight Entry – Straight Exit / 900 Door Opening
  • Automatic as well as Manual Mode